HPR-02 Self-Regulating Pumps
| HPR-02 |
—— |
55 |
75 |
105 |
135 |
165 |
210 |
105D |
125D |
280 |
165D |
| Max. displacement |
cm3/rev |
55 |
75.9 |
105 |
135.7 |
165.6 |
210.1 |
2x105 |
2x125 |
281.9 |
2x165.6 |
Max. operating speed w/o pressurizing
|
rpm |
2700 |
2500 |
2500 |
2350 |
2200 |
2100 |
2450 |
2400 |
2000 |
2100 |
| Max. oil flow |
l/min |
148.5 |
189.8 |
262.5 |
318.9 |
364.3 |
420.2 |
493.5 |
651.4 |
507.4 |
695.5 |
| Nominal pressure |
bar |
420 |
420 |
420 |
420 |
420 |
420 |
420 |
380 |
420 |
420 |
Peak pressure (intermittent)
|
bar |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
| Max. input torque |
Nm |
368 |
507 |
702 |
907 |
1107 |
1404 |
1245 |
1482 |
1884 |
1964 |
| Max. power |
kW |
104 |
132.8 |
183.8 |
223.2 |
255 |
308.8 |
319.4 |
372.5 |
394.7 |
442.2 |
Weight (approx.)
|
kg |
39 |
39 |
50 |
65 |
89 |
116 |
96 |
113 |
165 |
177 |
Design Features
- High pressure axial piston pump in swash plate design for open loop systems
- Clockwise or counter clockwise rotation
- Self-priming at high nominal speed
- Higher rotating speed by tank pressurization or swash angle reduction
- Adaptive noise optimization SPU
- Decompression fluid is drained via pump housing for suction side stability
- Exact and rugged load sensing controls
Control Method
- LS with hydraulic pressure cut-off
- LS with hydraulic override
- LS with electric override
- LS with hyperbolic power limitation
- LS with electro-proportional flow
- Electro-proportional flow setting, hyperbolic power
- Limitation and pressure cut-off
Product Advantages
- Optimal interaction with Linde LSC-directional control valves and LinTronic
- Energy saving operation by "flow on demand" control
- Dynamic response
- Self-priming at high nominal speed
- Adaptive noise optimization SPU
- Compact structure
- High power density
- High reliability
- Long life
Back to top